How many solar panels to connect to an inverter: string calculation

“How many solar panels can I connect to my inverter?” We hear this question every day.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ The answer depends not on the power you want, but on three figures: the panel voltage in frost, the inverter’s MPPT operating range and its input current. We will show the string calculation using the 630 W Tadiran TD630 panel and several hybrid inverters from our catalogue as examples.

String calculation for Tadiran TD630 solar panels for the inverter MPPT input

What a string is and why panels are connected in series

A string is several solar panels connected in series: the plus of one to the minus of the next.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ With this connection the panel voltages add up, while the current stays the same as for one panel. High voltage and low current mean thinner cables and lower losses, which is why for hybrid inverters with an input of up to 450–500 V panels are almost always assembled into a string.

With a parallel connection it is the other way round: the currents add up and the voltage does not change.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ Ready-made identical strings are connected in parallel if the inverter input allows that current.

The string is connected to the inverter’s MPPT controller. It constantly looks for the point at which the panels deliver the most power. We wrote in more detail about how much energy one MPPT array gives in the article on the output of 5 kW panels in London.

Tadiran TD630 panel specifications needed for the calculation

We take the data from the description of the Tadiran TD630 630 W solar panel (model TD630-TM10-132BD, N-Type TOPCon, bifacial):

Parameter Value What it is needed for
Power (STC) 630 W string power
Open-circuit voltage Voc 48.90 V maximum string voltage
Voltage at max. power Vmp 40.70 V operating voltage within the MPPT range
Current Imp / Isc 15.48 A / 16.18 A comparison with the input current
Power temperature coefficient −0.3%/°C losses in the heat
Dimensions / weight 2383×1133×30 mm / 33.7 kg roof space, mounting

Cold temperature and Voc: the main limitation

A solar panel’s voltage rises when it is cold.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ The highest voltage occurs on a clear frosty morning: the panel has not warmed up yet, but the sun is already shining. It is this voltage that must be compared with the inverter’s maximum input voltage.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ If it is exceeded, the inverter may fail.

The rated Voc of 48.9 V is given for 25 °C. Our panel description does not include the exact voltage temperature coefficient, only the power coefficient. That is why we allow a conservative margin of 15% for frost: for modern panels this is enough for frosts down to −25 °C. London is much milder: the lowest air temperature there in 2005–2023 was −9.5 °C (ERA5 data via PVGIS), so the margin is generous.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ Before installation we check the calculation against the datasheet of the specific batch of panels.

  • 8 panels: 48.9 × 8 ≈ 391 V, in frost ≈ 450 V. Below the 500 V limit.
  • 9 panels: 48.9 × 9 ≈ 440 V, in frost ≈ 506 V. Above 500 V, this is not allowed.

The second check: the string’s operating voltage (Vmp) must be within the MPPT range. For 8 panels it is 40.7 × 8 ≈ 326 V, which fits well within the 60–450 V range.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ In the heat the voltage drops, so a string that is too short, with 1–2 panels, can fall close to the lower limit. The minimum we install is 3 panels.

How many TD630 panels for a specific inverter

We take the inverter data from their descriptions, based on the manufacturers’ manuals:

Inverter Panel input Scheme with TD630
POWGROW SMS-5kW 24V 1 MPPT, 60–450 V, Voc up to 500 V, up to 27 A 1 string of 7–8 panels, up to 5.04 kW
EASUN SMS-6.5KP 6.5 kW 48V 1 MPPT, 60–450 V, Voc up to 500 V, 27 A, up to 9,000 W 1 string of 7–8 panels, up to 5.04 kW
GSIKE 11kW 48V 2 MPPT, 60–500 V, Voc up to 500 V, 2 × 5,500 W, current 18 A per input 2 strings of 8 panels, ≈ 10 kW
POWGROW 3.6kW 24V 1 MPPT, 18 A, up to 5,000 W; we plan the voltage no higher than 450 V 1 string of 7 panels, ≈ 4.4 kW
EASUN SMT-4KW 24V 1 MPPT, 60–500 V, up to 15 A the TD630 current (15.5 A) is higher than the input; a panel with a lower current is better

Why do we still install one TD630 string on inverters with an input of up to 9,000 W? Two strings in parallel would give a current of about 31–32 A, while the input is rated for 27–28 A. To use such an input fully, we select panels with a lower current.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ The GSIKE 11kW inverter has two independent MPPTs, so the two strings can be split between two roof slopes with different orientations. Read how to choose the angle and direction in the article on solar panel tilt angles.

If the inverter description has no data on the MPPT range or maximum Voc (for example, our description of the POWLAND SMS-5kW 24V does not list these parameters), we do not calculate “by eye”. We check the values against the label on the housing and the manual, and only then determine the number of panels.

How much energy such a string will give

A string of 8 TD630 panels is 5.04 kW. By our calculation for London, 5 kW of solar panels produce about 4,830 kWh a year allowing for all losses.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ In summer this is a significant part of a house’s consumption, in winter much less. A bifacial panel over a light surface can add a little more energy from the rear side, but in the string calculation we use the datasheet values and a current margin.

Important

A string of 8 panels has a voltage of over 300 V DC, and it appears as soon as light falls on the panels.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ Panel connection, surge protection and DC breakers are installed only by a qualified electrician. TD630 panels weigh almost 34 kg and are 2.4 m long, so we install them in pairs on a sturdy structure.

Frequently asked questions

Can I connect more panels than the inverter’s power?
Within the maximum input power specified by the manufacturer, yes.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ But the voltage in frost and the input current must always stay within limits.

Can different panels be mixed in one string?
It is not worth it. The string current is determined by the weakest panel, so different models lose part of their power.

What happens if one panel is shaded?
The output of the whole string falls, although the bypass diodes found in most panels partly smooth this out.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ That is why we place the string where shading is minimal.

How many panels are needed to charge the battery?
It depends on the battery capacity and consumption. For a typical house one 5 kW string already noticeably reduces charging from the grid.

Expert opinion

A string calculation is a check of three limits: the voltage in frost below the input maximum, the operating voltage within the MPPT range, and the panel current within the input current.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ For Tadiran TD630 panels and most hybrid inverters with an input of up to 500 V, that is 7–8 panels per MPPT. We always select panels for the specific inverter, not the other way round, because a mistake in the number of panels can cost you the inverter. We bring equipment from Europe, give a 1-year warranty, and our team of engineers has more than 1000 off-grid systems behind it.⁠‍‍​​​​​​​​​​​‌​‌‌‌​​‌​​‌‌​⁠ See solar panels and ready-made solutions in the photovoltaics section.

Send us your inverter model or tell us about your roof, and we will calculate the number of panels and carry out turnkey installation in Dnipro and the region. Call us: 093 293 93 93 or 099 054 40 38.