3-phase kit 19.5 kW (3 × POWGROW 6.5 kW) + Braun Power 51.2 V 628 Ah 32 kWh

247 500 UAH ≈ 5 446 $

Out of stock

Prices are in Ukrainian hryvnia (UAH). We ship to all countries. To order from abroad, contact us at +380 99 054 40 38 (Viber, Telegram, WhatsApp) and we will calculate delivery to your country.
SKU: dp-p-kit-3phase-19-5kw-braun32 Category:

Description

A 19.5 kW three-phase system with 32 kWh of storage: three hybrid inverters POWGROW SMS-6.5KP 6.5 kW 48 V that work in sync, each on its own phase L1, L2, L3, and a lithium cabinet Braun Power 51.2 V 628 Ah 32 kWh shared by all three.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ Together they provide a full 400/230 V grid for a home, workshop or small business, and during outages they keep the site running on the battery.

Who this kit is for

  • For houses and facilities with a three-phase supply that have three-phase pumps, motors or boilers.
  • For those who need both three phases of up to 6.5 kW each and an energy reserve for long outages.
  • For a powerful solar station: each inverter has its own panel input of up to 9000 W.

How long it runs without grid power

The cabinet’s usable energy reserve is approximately 26 kWh. Approximately:

1000 W ≈ 26 h
2000 W ≈ 13 h
5000 W ≈ 5 h
9000 W ≈ 2.9 h

The cabinet delivers up to 195 A, which is about 9 kW at the inverter output.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ Without the grid, keep the load exceeding solar generation within these limits; from the grid the system delivers about 18.5 kW: in parallel mode the inverters run at 95 % of rated power (per the datasheet). For more output from the batteries, cabinets are connected in parallel; we will pick the configuration for your site.

Kit advantages

  • True three-phase: 400 V phase-to-phase and 230 V phase-to-neutral, so three-phase motors and equipment work.
  • 19.5 kW total power: 3 × 6.5 kW (in parallel 95 % of rated, about 18.5 kW), peak up to 12 kVA per inverter.
  • The inverters and battery “talk” to each other: the cabinet with the JK BMS is connected by a RS485 cable to the first inverter, whose screen shows the battery’s charge, voltage and current.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ The protocol and all settings are in the kit manual.
  • Synchronization via parallel communication cables: the three inverters are connected in a ring; the diagram is in the kit manual.
  • Three solar inputs: each inverter has its own MPPT controller 60–450 V, up to 9000 W of panels.
  • Safe LiFePO4 chemistry: a cabinet on wheels, maintenance-free, designed for daily use.
  • Turnkey installation in Dnipro and the region: our electrician installs and configures the three-phase system.

Main specifications

Composition 3 POWGROW SMS-6.5KP 6.5 kW 48 V inverters and a Braun Power 51.2 V 628 Ah 32 kWh cabinet
Total power 19.5 kW (3 × 6.5 kW); in parallel 95 % of rated ≈ 18.5 kW; peak 12 kVA per inverter
Output 3 phases, 400 V phase-to-phase / 230 V phase-to-N, pure sine wave
Battery energy 32 kWh (51.2 V, 628 Ah, LiFePO4, 16S)
Continuous output from the battery up to 195 A (≈ 9 kW at the inverter output)
Solar panel input (per inverter) up to 9000 W, MPPT 60–450 V, Voc up to 500 V, up to 27 A
Inverter ↔ battery communication RS485, PYLON protocol (item 44 = PYL)
Transfer time typically 10 ms
Monitoring Wi‑Fi, Bluetooth on the cabinet
Max. charging current from the 220 V grid 120 A per inverter
Max. solar charging current 120 A per inverter
Max. total charging current (solar + grid) 120 A per inverter
Grid voltage range 90–280 V (“appliances” and generator modes), 170–264 V (UPS mode)
Max. bypass current (from the grid) ≈ 40 A (≈ 9.2 kW of load), as in the J6500HC on the same SMS-6.5KP platform (per inverter)
Battery operating voltage range 43.2–58.4 V
Inverter dimensions 440 × 335 × 117 mm (each)
Inverter weight 9.4 kg (each, total 28.2 kg)
Battery dimensions 800 × 630 × 430 mm
Battery weight 236 ± 2 kg
Total kit weight ≈ 264.2 kg

The kit includes

  • Inverter POWGROW SMS-6.5KP 6.5kW 48V × 3
  • Battery Braun Power 51.2V 628Ah 32kWh

Our products come from Europe. High quality, 1-year warranty.

Recommended: power cable sets for the inverter

All of the system’s current flows through the cables between the battery and the inverter — under load that means tens or even hundreds of amps.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ That is why we recommend taking our M8–M8 power cable set (“+” and “−”) made of 25 mm² copper cable right away. We crimp the lugs ourselves on a professional press with a hexagonal die, not with pliers or a hammer.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ The copper strands and the sleeve are compressed into a single whole, so the contact has minimal resistance, does not heat up and does not loosen over the years. The cables are ready to install: bolt them to the terminals and you can switch on.

Cross-section of a MinerTech crimped lug
Cross-section of our lug: solid copper with no voids.

Choose the length:

The shorter the cable, the lower the losses, so choose the shortest one that still lets you place the equipment comfortably.⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ A three-phase kit needs a separate cable set for each inverter. You can see how we crimp the lugs in the video on the cable page. Not sure about the length?⁠‍‍​​​​​​​​​​​‌‌​​​‌​‌‌‌​‌​⁠ We will advise you by phone.

We will select equipment for your specific task. Advice from a technical specialist: +38 099 054-40-38.